Pvc Insulated Submersible Cable (Kf & Kr Series) |
|
|
|
|

CONSTRUCTION
High
conductivity annealed and bunched flexible copper conductors are made from
electrolytic bright copper twisted together and insulated with colour coded
special grade water proof flexible PVC compound. The final protection of outer
sheath is made from high grade flexible PVC / Rubber compound impervious to
water, grease, oil etc., there by it ensures long life and has good withstanding
capacity to high voltage and current. The cables can be used for supplying
power to all types of indoor and outdoor portable and fixed pumping equipments.
These cables are sequentially marked at one-meter intervals for convenience.
Specifications
|
Available sizes in
Sq.mm |
1.5, 2.5, 4,6,10,16
& 25
3 core and 4 core |
|
Voltage Rating |
1100 V |
|
Temperature range
Conductor |
-10OC to
+ 70OC
High conductivity
annealed and
bunched copper |
|
Insulation material |
Flexible water proof
PVC |
|
Sheath material |
Flexible water proof
PVC / Rubber |
|
Sheath color |
Black & Blue |
|
Core color |
3 Core - Red, Yellow
and Blue
4 Core - Red,
Yellow, Blue and Green |
Applications
Supplying power to all types of indoor and outdoor portable and fixed pumping
equipments
Special Features
High conductivity annealed and bunched flexible electrolytic bright copper
conductors, High grade flexible PVC insulation and PVC / Rubber sheath, Good
withstanding capacity to high voltage and current, Sequently marked at one meter
intervals for convenience.
Note : Do not use
single sheath cables for heavy-duty applications like sewage, slurry and de
watering pumps in which the acidic fluids and chemicals will damage the sheath.
Double-sheathed cables can be used for these kind of applications. Double
sheathed cables can be supplied on request.
Technical
Data
3 - Core Flat Cable - PVC
Insulated and PVC Single sheath.
Conductor
Area
(in sq.mm)
(Nominal)
|
No. of
strands
and Diameter
(Nominal)
|
Thickness of
insulation
(in mm)
(Nominal)
|
Thickness of
Sheath
(in mm)
(Nominal)
|
Maximum overall
Dimensions
(in mm)
|
Maximum
Conductor
Resistance
At 200C
Ohms/km
|
Current
carrying
capacity
at 400C
in Amps
|
W
|
H
|
1.5
|
22 /0.3 |
0.8 |
1.15 |
12.8 |
6.0 |
13.3 |
14 |
2.5
|
36 /0.3 |
0.9 |
1.15 |
14.6 |
6.4 |
7.98 |
18 |
4
|
57 / 0.3 |
1.0 |
1.15 |
17.2 |
7.04 |
4.95 |
26 |
6
|
85 /0.3 |
1.0 |
1.15 |
18.7 |
7.9 |
3.30 |
31 |
10
|
140 / 0.3 |
1.0 |
1.40 |
23.7 |
9.9 |
1.91 |
42 |
16
|
226 / 0.3 |
1.0 |
1.40 |
28.0 |
11.4 |
1.21 |
57 |
25
|
354 / 0.3 |
1.2 |
2.00 |
35.5 |
14.7 |
0.78 |
72 |
|