These centrifugal single or multi stage vertical pumps are
ideally suitable for openwells where there is wide
fluctuations in water level. This works under water and it
rests at bottom of the well. Hence, suction and priming
problems do not arise. Pump portion is of single or multi
stage and are fitted with cast iron casing and impellers.
Pump�s
volute chamber is designed to give the best possible
hydraulic efficiency. Dynamically balanced impellers offer
vibration free operation with long life. Prime mover is
water filled, rewindable, water lubricated and water cooled
submersible motor. It features water lubricated thrust
and journal bearings. Specially designed high
performance thrust bearings are used that can withstand
axial thrust loads with minimum wear & tear. The unique
design of thrust bearings create a wedge of water between
the shoe and the disc and thereby it gives better water
lubrication and increases the life cycle of the thrust
bearings. The stator is wound with special water proof
bi-axially oriented synthetic film insulated winding wires
and made up of low watt loss steel laminations assembled
under pressure, rigidly locked in a stator shell.
Dynamically balanced rotor maintains uniform clearance,
thereby it gives better efficiency and increases the life
cycle of the bushes and motor. Motor sealing is made by
means of grommets ,
�O�
rings, shaft seals and sand guard to avoid ingress of well
water / sand into the motor. Pressure equalizing rubber
diaphragm is provided to guard the pressure and volume
variations of water inside the motor. Motor is pre filled
with clear, cold, pure, fresh filtered water. However, on
request, motors can be pre-filled with water and propylene
glycol (Anti-freeze agent) for places where the temperature
is below the freezing conditions. Before commissioning
ensure the pre filled level of water inside the motor. If
any loss of volume is noticed, refill with clear, cold,
pure, fresh filtered water through water filling plugs.
Should the use of anti - freeze agent mixed water not be
allowed for special applications, these motors can also be
filled with clear, cold, pure, fresh, filtered water and
operated. These Submersible pumps require an adequate motor
protection control panel.
Applications
Garden, Irrigation, Drip & Sprinkler irrigation, Public
water supply, Industrial & rural water supply.
Pump
operating Limitations
|
Flow rate upto |
lps |
17 |
|
|
m3/h |
61.2 |
|
Total Head Range |
m |
10-122 |
|
|
ft |
33-400 |
|
Nominal Outlet size |
Inches |
2, 2 " & 3 |
|